HF-P 2 14-35 TL5 HE III 220-240V
PHILIPS

HF-P 2 14-35 TL5 HE III 220-240V

Regular price ₱700.00 ₱0.00 Unit price per

General Information

Application Code

III

Type Version

IDC

Lamp Type

TL5 HE

Number of Lamps

2 piece/unit

Number of Products on MCB (16A Type B) (Nom)

28

Automatic Restart

Yes

Operating and Electrical

Input Voltage

220 to 240 V

Input Frequency

50 to 60 Hz

Operating Frequency (Nom)

45 kHz

Ignition Method

Programmed Start

Crestfactor (Max)

1.7

Power Factor 100% Load (Nom)

0.99

Ignition Time (Max)

0.9 s

Mains Voltage Performance (AC)

-8%-+6%

Mains Voltage Safety (AC)

-10%-+10%

Earth Leakage Current (Nom)

0.5 mA

Inrush Current Width

0.25 ms

Constant Wattage Deviation

-2%/+2%

Ballast Factor (Nom)

1

Power Losses (Nom)

2-5.5 W

Inrush Current Peak (Max)

24 A

Wiring

Connector Type Input Terminals

WAGO 251 universal connector  [ Suitable for both automatic wiring (ALF and ADS) and manual wiring]

Cable Capacity Output Wires Mutual (Nom)

200 pF

Connector Type Output Terminals

WAGO 251 universal connector  [ Suitable for both automatic wiring (ALF and ADS) and manual wiring]

Cable Length Hot Wiring

0.75 m

Wire Striplength

8.0-9.0 mm

Dual Fixture Master/Slave

Not applicable  [ Master/Slave oper. not applicable]

Input Terminal Cross Section

0.50-1.00 mm²

Output Terminal Cross Section

0.50-1.00 mm²

Cable Capacity Output Wires to Earth (Nom)

200 pF

System characteristics

Rated Ballast-Lamp Power

14-35 W

Rated Lamp Power on TL5 HE

14/35 W

System Power on TL5 HE

36.8/75.6 W

Lamp Power on TL5 HE

28.0/70.0 W

Power Loss on TL5 HE

2.8/5.6 W

Temperature

T-Ambient (Max)

60 °C

T-Ambient (Min)

-25 °C

T-Storage (Max)

80 °C

T-Storage (Min)

-40 °C

T-Case Lifetime (Nom)

80 °C

T-Case Maximum (Max)

80 °C

T-Ignition (Max)

60 °C

T-Ignition (Min)

-25 °C

Mechanical and Housing

Housing

L360x30x22

Emergency Operation

Nominal Light Output After 60 Seconds

100% of EBLF

Battery Voltage Lamp Ignition

176-276 V

Normal Operating Voltage (DC)

220-240 V

Battery Voltage Lamp Operation

176-276

Battery Voltage Guaranteed Operation

176-275 V

Battery Voltage Guaranteed Ignition

186-275 V

Emergency Ballast Lumen Factor (EBLF) (Nom)

100 %

Nominal Light Output After 5 Seconds

50% of EBLF